Keep that chamber toasty
48
115
0
1661
updated December 27, 2023

Description

PDF

Camber heater with derby shield.

It is secured by the enclosure panel bolts with no modifications.

I installed the a thermal fuse between the PTC heater core and cover.  


You will need:
1 x PTC 400w heater
1 x 220v fan
2x M3x50
2x M3x40
2x M6x16
1x SSR (min 3A)
1x 120degC thermal fuse


[heater_generic chamber_heater]
sensor_type: ATC Semitec 104GT-2
sensor_pin: PF5
heater_pin: PD12
control: watermark
#smooth_time: 30.0
max_delta: 2
#target_temp: 20
max_power: 1.0
min_temp: 0
max_temp: 65

[verify_heater chamber_heater]
check_gain_time: 240
heating_gain: 0.1

 

Test results:
Setup
-V-Core 500
-4 mm PC panels
-sensor placed  300 mm above the nozzle
-Bed was just above the bed during testing
-No other heating related mods

Readings
Ambiant temp = 22degC
Only chamber heater on for 30 min = 35.7degC
Only bed at 105degC after 60 mins  = 46.1degC
Chamber heater + bed at 105degC after 60 mins = 53.5degC
https://discord.com/channels/582187371529764864/856894754435104778/942454371046817793

Model origin

The author marked this model as their own original creation.

License