This remix of this nice Big Einsy Case is optimized with Plug & Play for Maintenance. My idea was to get the printer quick out of my enclosure, which was a little hassle until these successful upgrade, because the Power Supplier and LCD are removed from the printer and they are outside of the enclosure.
Shopping List
2x D-SUB Plug female, 15-pole, for IDC-Ribbon cable (Link, Reichelt) for LCD (P1 & P2) at Einsy side
2x D-SUB Plug male, 15-pole, for IDC-Ribbon cable (Link, Reichelt) for LCD (P1 & P2)
1x Wire like this one or you can cut the original power supply wires
4x Cable lugs like the red open ones if you want to make new cable and not use the original power supply wire.
Heat shrink tubing (optional)
8x Screw M2x 8 mm, socket head cap
4x Nut M2
1x 40x40 fan for the cover (optional, see original creator)
1x Soldering Skills (not optional for this setup)
1x Multimeter for checking the soldered cable.
Print
1x Big Einsy Case - Plug & Play
1x Cover from original creator.
1x all other small parts from original creator.
Assembly
Cable
ATTENTION!!!
!!! if you have an external LCD or want to install it outside, make sure the Ribbon is shorten then 0,5 m. From my experience I can tell, that if the cable is longer then 0,5 m the LCD will not work, because of the SPI-Communication Protocol. The SPI required short ways and fast feedbacks, because it is created for communication on PCBs. !!!
!!! Make sure the device is unplugged when doing this work!!!
!!! Make sure when you cut the cable and or building new cable that you have an eye on the connection directions of the connectors !!!
P1 Cable inside case
length of Ribbon Cable about 13-15 cm,
Power Panic cable, cut it to about 10 cm from Einsy Connection side
right side, IDC connector, 10-pole
left side, D-Sub connector, 15-pole
connect the Ribbon Cable to the right side and the Power Panic Cable to the left of the connector. (I first connected the Ribbon Cable and closed the connector to fix the Ribbon Cable. After this I reopened the connector again and inserted the Power Panic Cable)
P2 Cable inside case
length of Ribbon Cable about 13-15 cm
right side, IDC connector, 10-pole
left side, D-Sub connector, 15-pole
connect the Ribbon Cable to the right side
Power Supply Cable inside case
Lenghts of power supply cable 6-8 cm, 2x
solder the wire on the RC-Power Plug and cover it with heat shrink tube.
if needed press the cable lugs on the cable.
MMU Cable (I'm sorry, I forgot a to make a good picture of both ends)
Hold the Einsy Case in place on the printer and mark the length of the MMU Cable where the cable reach the opening on the top. Make sure that the cables are not stretched but loosely reach the case.
Solder each cable on the male and female connector. Make sure after you finished soldering the first connector that all connections are working.
Solder the second connector and make sure the right cable are meeting.
My soldering overview. I also covered the cable with on heat shrink tube.
Cable from Power Supply and LCD
basically repeat the first cable steps to build the other side of the connection and make sure that you use the counterpart of the connector and connecting the cables the right way.
Case Assembly and Wiring
Install the case on the Printer
Install the Einsy into the case
Start wiring according Prusa manual.
Here my wiring result.