I tried to get my eddy probe offset from measuring in fusion but something seemed off. 

I modeled the bottom of the eddy probe with a little dot to show where the sensor should be measured from and the point at which its pointed. 

I homed my printer and then placed my little tool under the probe. I've made it so it should be flushed with the back and side walls of the probe.

Take note of the current X and Y

Raised the z a bit and then through klipper, moved the actual nozzle over the hole. Make sure to baby step it.

Depending on where your probe is then subtract whats moved. 

 

Example: I set my nozzle x to 309 and y to 60. Its easier to the nozzle tip if it's at the edge of the bed. 

Then placed my tool under the eddy probe.

The I moved my nozzle to where the prob is which is x 257.1 and Y 41.5.

That gave me an offset of x-51.9 and y-18.5.

When i measured it from fusion it was -53 and -18. Not a lot but it makes a difference. 

 

I've added add holes on the bottom to add little magnets.  

The ones I used are 6mm by 2.55